China FW-2 High Negative Pressure Gas Sampler Technical Manual - China Supplier China FW-2 High Negative Pressure Gas Sampler Technical Manual - China Supplier China FW-2 High Negative Pressure Gas Sampler Technical Manual - China Supplier China FW-2 High Negative Pressure Gas Sampler Technical Manual - China Supplier China FW-2 High Negative Pressure Gas Sampler Technical Manual - China Supplier

FW-2 High Negative Pressure Gas Sampler Technical Manual

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 艾迪
Spec: FW-2


Contact Info
  • Add:高新区西四环228号, Zip: 450000
  • Contact: 艾迪
  • Tel:0371-86553011
  • Email:2513586002@qq.com

Other Products

Description
Additional Information

FW-2 High Negative Pressure Gas Sampler Technical Manual
Product Overview
The FW-2 High Negative Pressure Gas Sampler is a professional sampling device specifically designed for coal mine gas extraction systems, suitable for collecting gas samples under various negative pressure conditions. This product features a modular design, offering ease of operation, precise sampling, and portability.
Technical Parameters
Item Parameter Working Negative Pressure Range 0-85Kpa Total Weight 1.3kg±0.1kg Operating Temperature -20℃~60℃ Relative Humidity ≤95% Sampling Volume 100mL

FW-2 High Negative Pressure Gas Sampler Structural Components
1. Inlet Connector Assembly (including rubber plug valve)
2. Outlet Connector Assembly
3. Piston-Type Air Extraction Mechanism
4. Aluminum Alloy Air Cylinder
5. Special Rubber Seal Ring Set
6. Telescopic Pull Rod
Operating Specifications
Pre-Sampling Preparation
1. Check the sealing of all connecting components
2. Securely connect the inlet interface to the orifice flow meter measurement nozzle
3. Properly align the outlet interface with the gas detector
Sampling Process
1. Slowly pull the rod to its maximum stroke (negative pressure sampling phase)
2. Hold still for 3 seconds to ensure gas sample stability
3. Quickly push the piston to complete gas sample transfer (positive pressure output phase)
Precautions
• Regularly inspect seal ring wear • Avoid severe vibration and impact • Clean the air path promptly after sampling • Store in a dry and ventilated environment
Maintenance
Professional calibration is recommended quarterly, with full seal replacement annually.

Zhengzhou Aidi ProductionFW-2 High Negative Pressure Gas SamplerSupplies coal drill cuttings desorption instrument, deep hole sampling device, pressure measuring instrument, geological exploration desorption instrument, borehole flow meter, mine extraction and outburst prevention equipment, true density measuring instrument for coal, gas content measuring instrument, automatic initial gas emission speed measuring instrument, diffusion speed measuring instrument, gas parameter instrument for coal extraction pipelines, borehole coal powder circulation device

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 艾迪
Spec: FW-2
Stock:
Origin: China / Henan / Zhengzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192